Home | Support | Inquiry | Career | Contact UsDealers                       
Home > Product > Clean Room / Parma / HVAC
 
UT-6001 | TEMP. AND HUMIDITY INDI. CONTROLLER
 
   Datasheet | Manual
 
Controller size : 96x96 Sensor : FLP / duct mounted and wall mounted Ex. Flameproof with S S box
 
Feature:-

► FDA 21 CFR part 11 - GAMP-4 compatible.
► Micro controller based Temp.+Rh indicator controller in single enclosure.
► All channel are programmable ranges and unit (Through Front key pad).
► Highly stable Temp.+ Rh sensor Available with different mounting.
► Potential Free Relay contact output For Temp. and Rh() up to 4 nos.
► Process parameter High and Low LEDs status indication for Both channels.
► MODBUS RTU multi drop RS-485 serial communication for PLC, SCADA etc.
► Password protection for calibration and programming mode.
► Software base Calibration for both channels.
► User programmable offset correction.
► Wall mounting/FLp and Duct mounted Sensor available.
► Isolated 2 X 4-20mA Retransmission output for Temp & Rh.
► Transmitter loop power supply with current limit as standard.
► Power supply :230V/110V AC. Or 24V/12V DC
► Sensor Accuracy : RH - 2% / 3% , Temp.- 025 % of Span.
► Ex. Flameproof model available for Hazardous applications..

 
Application:-

► Stability chambers.
► Clean room applications.
► Laboratory and scientific instruments.
► Parma Environments monitoring application.
► Where Temp. and humidity indication and control require.

 
FDA 21 CFR part 11 compliance data logging computer software available (SCADA).
 
Specification For Controller:-
Input Nos. of input 2 nos. (TEMP + RH)
Temperature input External:4-20 mA or 0-10 V / RTD PT-100)
Humidity input External: 0.8 to 3.9 V dc /0-5 v dc /4-20 mA or 0-10 V DC)
Transmitter power supply 24V/5V DC @ 30 mA max, isolated from I/P & O/P
Indication Temperature Channel-1: 4 digit 0.56” LED Seven segments display
Humidity Channel-2: 4 digit 0.56” LED Seven segments display
Range Temperature Programable with decimal point.(0 to 60 *c)
Humidity 0 to 100.0 % with decimal point.
Display Resolution 000.0 for temp and humidity
Accuracy Temperature 0.25 % on FS for Temp. input
Humidity 0.1 % for Rh input
Output Relay Output 1 / 2 / 3 / 4 Relays NO - C - NC Contacts , 5A@240 V AC Resistive
SSR Output 24VDC @ 20 mA ,12VDC @ 20 mA
Re transmission Current & Voltage outputs 0~20/ 4~20 mA, 0~5V, 0~10V, 1~5V DC, fully 3 port isolated 1.5KV
Communication Communication Protocol Modbus RTU RS- 485 isolated communication.
Programmable parameter Baud rate , Parity , Node address , Stop bit.(minute and hour)
Read /write parameter Read: Process value ,Decimal point Write: High Low set point
No. of slave ID Total 1-256 unit
Parameters Set point / High scale / Low scale/Time(MM+HH) Full range as per input selection
Programming of parameters Through 4 tactile keys (with password protection)
Alarm logic Full Scale High or Full Scale Low
Other Mounting Bricks and modules wall Flush panel mounting
Enclosure MOC M S powder coated enclosure
Supply voltage & Power consumption 230 V DC & as per on display size
Operating ambient Temperature and Humidity Temp: 0~60 °C, Humidity: Below 90%, non condensing
 
Specification For Sensor:-
Range Temperature 0 to 60 *c
Humidity 0 to 100.0 % with decimal point.
Accuracy Temperature 0.25 % on FS for Temp. input
Humidity +/- 3 % of span.
Repeatability Temperature 0.1 % on FS.
Humidity 0.5 % on FS.
Output Temperature RTD pt100 or 4-20 mA / 0-10 v dc
Humidity 0.8 to 3.9V dc / 4-20 mA / 0-10 v dc
Mounting Wall mounting , duct mounting ,chamber mounting, flame proof.
 
 
Datasheet | Manual